Cooling Tower Service

MechPro Inc. Cooling Tower Service includes:

  1. Removal of  hot decks
  2. Repetitive spraying of solution to break down buildup through the nozzles in the top to penetrate the fill.
  3. Spraying the outside and the inside of the fill with the same solution.
  4. Light power washing and physical cleaning to clean the fill.
  5. Removal of all loose debris from the pan on both the inside and  the outside.
  6. Jetting the balance line.
  7. Replacement of the hot deck covers.
  8. During the cleaning process most water is filtered and recirculated to reduce  impact on any sensitive areas that most of our large customers are trying to be cautious of.
  9. Digital photos are provided for all projects to document the before-and-after condition of the system and to document that areas are properly serviced.

This job was a series of 6 connected Cooling Towers,  each being 12″ x 12″  and 20″ off the ground.

Cooling Tower Cleaning Service 1
Cooling Tower Cleaning Service 2

A proactive, regularly scheduled cleaning of cooling towers is essential for any facility to manage the HVAC system’s hygiene and to maintain peak operating efficiency. MechPro Inc.’s cooling tower service removes bacterial decontamination as well as flushes away dirt, debris and sediment build up on the fill and settle in the basin.

All cooling tower cleaning services are performed by trained and skilled MechPro cooling tower cleaning technicians who follow all OSHA and any site-specific safety guidelines.

MechPro follows best practices and utilizes state-of-the-art equipment when providing cooling tower cleaning services.

According to The United States Occupational Safety and Health Administration’s (OSHA) Technical Manual, all cooling towers should be thoroughly disinfected at a minimum of twice per year.

Normally this maintenance will be performed before initial start-up at the beginning of the cooling season and after shutdown in the fall.

Towers which exhibit high levels of biological contamination should be cleaned immediately and towers that have been out of service for long periods of time should be cleaned before they are returned to service.

Pricing and Costs associated with Cooling Tower Cleaning

MechPro’s Cooling Tower Cleaning Service pricing is based on multiple factors including, but not limited to, the size of the cooling tower cells, the number of cells, location of the towers, and overall cooling tower condition.

Call MechPro Inc. today at (800) 249-6709  for a quote and to schedule your quarterly, bi-annual or annual Cooling Tower Cleaning Services.

 

 

Filed Under: Cooling Towers Tagged With: bacteria, basin, cleaning, cooling tower, debris, dirt, fill, MechPro, power washing, service, settle

Heat Exchanger Quote Request

Contact us with your questions, concerns and service issues.
(800) 249-6709

Search

RECENT POSTS

  • Keel Cooler Cleaning
  • MechPro Inc. Provides Marine Vessel Tube and Shell Heat Exchanger Service
  • Frozen Heat Exchanger Troubleshooting
  • MechPro Provides HVAC Heat Exchanger Service
  • MechPro Inc. Shell and Tube Heat Exchanger Pressure Test

Updates

MechPro Inc. Keel Cooler Cleaning service before-and-after

Keel Cooler Cleaning

December 11, 2018 By The Heat Exchanger Expert

MechPro was recently contacted by a major American Seafood company to provide Keel Cooler Cleaning service for one of their commercial fishing trawlers.  Once the trawler was in drydock the keel cooler was removed from the exterior hull of the vessel and arrangements were made for pickup and delivery to MechPro’s shop. Over time Keel Coolers, which […]

MECHPRO INC. COMPANY PROFILE

  • 24/7 Service Availability
  • Servicing all 50 States
  • On-Site Services
  • Competitive Rates
  • Multiple T.W.I.C. Card Holders
    • Contact us with your questions, concerns and service issues.
      (800) 249-6709

MechPro was recently contacted by a major American Seafood company to provide Keel Cooler Cleaning service for one of their commercial fishing trawlers.  Once the trawler was in drydock the keel cooler was removed from the exterior hull of the vessel and arrangements were made for pickup and delivery to MechPro’s shop. Over time Keel Coolers, which […]

RECENT POSTS

  • Keel Cooler Cleaning
  • MechPro Inc. Provides Marine Vessel Tube and Shell Heat Exchanger Service
  • Frozen Heat Exchanger Troubleshooting
  • MechPro Provides HVAC Heat Exchanger Service
  • MechPro Inc. Shell and Tube Heat Exchanger Pressure Test
  • Plate and Frame Heat Exchanger Repair

EXTRA

    • WARRANTY
    • PRIVACY POLICY
    • TERMS OF USE
    • SITE MAP

SEARCH

Social Media

  • Facebook
  • Google+
  • LinkedIn
  • Pinterest
  • Twitter
  • YouTube

TAGS

24/7 2017 acid AHR Expo chemical cleaning CIP cleaning convention Cummins Model QSK 50 facility gasket gaskets heat exchanger heat exchanger plates heat exchanger repair heat exchanger service inspection Las Vegas maintenance marine marine vessel MechPro metal OEM on call Pacific Northwest PHE Plate Heat Exchanger plate heat exchanger service plates Portland repair replacement replacement gasketes replacement gaskets rubber gaskets seals Seattle Seattle Heat Exchanger service Shell and Tube ship slider Tacoma tube and shell

MechPro, Inc.
1320 26th Street N.W. #4
Auburn, Washington  98001

Toll Free: (800) 249-6709
Alternate Phone: (206) 445-5230

Copyright © 2019 · Website Services by Image Market Inc.